After replacing a failed Compute Module, you notice the server profile Is not automatically assigned to the replaced server hardware. What can cause this issue?

Options:

A.

IL0 firmware of the replacement server is different than firmware in broken server.

B.

Server profile affinity is configured to Device Day + server hardware.

C.

The enclosure group has to be updated to match the original enclosure group.

D.

The replacement server has more memory or CPUs than broken machine.

Buy Now
Questions 5

What step must be taken to add an HPE SuperDome Flex to an existing OneView environment

Options:

A.

A Rack Management Controller must be added to HPE OneView.

B.

HPE Superdome Flex can be added to HPE OneView after at least one nPAR is created.

C.

Each HPE Superdome Flex chassis must be added Individually using BMC IP.

D.

HPE Superdome Flex complex can be added by adding base chassis of this complex.

Buy Now
Questions 6

Your customer plans to monitor HPE ProLiant DL systems and HPE BladeSystem using HPE OneView Which license is required to accomplish this task?

Options:

A.

HPE One View Global Dashboard license

B.

HPE OneView Advanced license

C.

HPE composer 2 license

D.

HPE OneView standard license

Buy Now
Questions 7

Click the option that must be configured for an HPE OneView when an HPE storage system is connected directly to an HPE Synergy frame.

Options:

Buy Now
Questions 8

what is required to add a remote frame to the primary management ring?

Options:

A.

UUD of the remote HPE Composer

B.

Serial number of one of the remote frames

C.

Remote frame Link Module IPv6 address

D.

Request code from the primary HPE Composer

Buy Now
Questions 9

Which statement about a Logical Enclosure for HPE BladeSystem is Hue?

Options:

A.

A logical enclosure can have between 1 to 5 HPE BladeSystem c7000 enclosures.

B.

A logical enclosure must be created only for monitored HPE BladeSystem C700O enclosures.

C.

A logical enclosure is created automatically, and it is always based on a single enclosure.

D.

A logical enclosure can contain a mix of HPE BladeSystem c7000 and C3000 enclosures.

Buy Now
Questions 10

Refer to the exhibit.

Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?

Options:

A.

There are not sufficient frames for highly available setup.

B.

Some master modules only support a redundant setup.

C.

Firmware on the master modules is too low to support highly available setup.

D.

A dedicated license must be added to HPE OneView to enable this feature.

Buy Now
Questions 11

What is the best practice when deploying an HPE OneView appliance?

Options:

A.

Enable VMware Fault Tolerance if the appliance is deployed to a VMware hypervisor.

B.

deploy the appliance in a hypervisor cluster that Is not managed by OneView.

C.

Use thin-provisioning for the HPE OneView appliance to save storage capacity.

D.

Deploy two HPE OneView appliances and configure them in HA mode.

Buy Now
Questions 12

Click the option that will prevent the appliance from sending any email notifications or forwarding any SNMP traps that are related to the server hardware.

Options:

Buy Now
Questions 13

Which statement about an HPE OneView server profile is true?

Options:

A.

A server profile can be created only for HPE BladeSystem, HPE Synergy, and HPE Superdome Flex servers.

B.

A server profile created for a specific server hardware type cannot be moved to a server with a different server hardware type.

C.

A server profile can be used to configure a local storage controller, but cannot be used to configure SAN-based storage.

D.

A server profile can be used to update firmware and drivers when the operating system on the server is up and running.

Buy Now
Questions 14

Refer to the exhibit.

Your customer created multiple networks in HPE OneView, but only Eth-1 is available to be used within a server profile. What is a likely cause of this situation?

Options:

A.

The other networks are not configured with the required Smart Link parameter.

B.

The other networks are not added to the Logical Interconnect Group configuration.

C.

The other networks have Private Network' selected, which hides them from Compute Modules.

D.

The other networks are configured with a purpose other than General or Management.

Buy Now
Questions 15

You try to add an HPE Primera array to HPE OneView, but you get a connectivity error. However, you can connect to the array using SSMC. What should you verify before adding HPE Primera to HPE OneView?

Options:

A.

whether WSAPI service is enabled on HPE Primera array.

B.

whether the appropriate license for HPE Primera Is available in HPE OneView.

C.

whether array management using HPE OneView is enabled in SSMC.

D.

whether there are at least two Fibre Channel networks defined in HPE OneView.

Buy Now
Questions 16

Your customer plans to use HPE OneView to manage a small environment based on HPE ProLiant servers that includes G7 and Gen 10 systems. What should you explain to this customer?

Options:

A.

HPE Management Agent must he installed for HPE ProLiant Gen 10 servers.

B.

HPE ProLiant G7 and Gen10 cannot be managed using the same appliance.

C.

Not all of the features will be available for HPE ProLiant G7 systems.

D.

HPE ProLiant Gen 10 servers do not need an HPE OneView license.

Buy Now
Questions 17

Click the option from the HPE OneView main menu that will allow you to define UPS or other components that will work as a placeholder in a rack system.

Options:

Buy Now
Questions 18

What event occurs on iLO when an HPE ProLiant server is added to HPE OneView?

Options:

A.

IPMI credentials are configured for the iLO

B.

REST API plugin is enabled for iLO

C.

Active Directory configuration is performed on iLO

D.

SSO certificate is added to the iLO

Buy Now
Questions 19

Which types of support dump can be created using HPE OneView? (Select two.)

Options:

A.

Enclosure group support dump

B.

Appliance support dump

C.

Firmware deployment support dump

D.

Logical enclosure support dump

E.

Maintenance console support dump

Buy Now
Questions 20

Which statement about HPE OneView Global Dashboard is true?

Options:

A.

It is an application that can be installed on Windows or Linux system that will provide automated discovery of HPE OneView instances

B.

It is a plugin to HPE Oneview that will allow integration of HPE oneView with VMware management and monitoring components

C.

It is a virtual appliance that can aggregate health and inventory information from multiple HPE OneView appliances or HPE Composers

D.

It is a plugin to vCenter Server that will allow management of the components added to HPE Oneview from vCenter server interface

Buy Now
Questions 21

You configured downlink aggregation for one of the HPE Synergy Compute Modules in an environment by placing two connections in the same Link Aggregation Group. After you made the changes to the server profile, its status changed to critical.

What can be done to fix this issue?

Options:

A.

The teaming or bonding driver in the server OS must be configured to enable the LACP and to form the LAG correctly.

B.

The server profile for a given HPE Synergy compute module should be reapplied, then the Compute Module should be rebooted.

C.

Link Aggregation Group functionality should be enabled in advanced properties of the Logical Interconnect.

D.

Ensure that the Link Aggregation Group time-out value matches the server set values.

Buy Now
Questions 22

Which statement about the presented storage pools is true?

Options:

A.

Storage pools in discovered state can be removed from HPE OneView.

B.

HPE OneView can be used to configure replication only between managed storage pools

C.

All storage pools from the system named ThreePAR-1 can be used for volume provisioning

D.

All storage pools in managed state have a valid HPE OneView license applied

Buy Now
Questions 23

Which statement about server hardware types is true?

Options:

A.

Once selected in the server profile, the server hardware type cannot be changed, and a server profile can be moved only between the same type of servers

B.

Server hardware type can be defined only for HPE Synergy and HPE BladeSystem, but it cannot be defined for HPE ProLiant or Apollo systems

C.

Administrator has to manually define the server hardware type for any unique server architecture and mezzanine card combination

D.

The server hardware type is automatically created when a server with unique architecture and mezzanine card configuration is added to HPE OneView

Buy Now
Exam Code: HPE2-T37
Exam Name: Using HPE OneView
Last Update: May 18, 2024
Questions: 79
$64  $159.99
$48  $119.99
$40  $99.99
buy now HPE2-T37