Which HPE solution brings together CPU, Memory, and Disk with an unpredictable workload into a single management infrastructure?
A customer is experiencing read cache hit ratios well below 80 percent on an HPE Nimble HF40 array Data is constantly being ejected from the Nimble array's First In First Out cache
What should you recommend?
A retail company recently implemented a Video surveillance solution. They now need an MSA storage solution with 100TB capacity. They want to be able to add more disk capacity if needed.
Which HPE tool can help you choose a storage solution, determine the total usable capacity, and create a BOM?
For which virtualization management products does HPE OneView offer integration plug-ins1? (Select two.)
HPE Support asks you to generate an SSD wear gauge report for local storage on an HPE DL360 Gen10 server running VMware.
Which procedure will ensure that the server will boot directly into a maintenance state so you can generate the requested report?
A customer environment is being managed and monitored with HPE OneView. A review of the OneView log shows that there have been several trap storm events.
Which series of events must take place for OneView to insert a Trap Storm event entry into the log of system events?
Indicate whether each management feature manages or monitors a single system or multiple systems.
You configured a port on an HPE FiexFabric 5900 series switch that is connected to a VMware ESXi server to support multiple VLANs
interface Ten-GigabitEthernet 1/0/11 description server ESXiOl-ethl port link-type trunk port trunk permit vlan 50 port trunk permit vlan 2 port trunk pvid vlan 50
Given the configuration above, what should happen to any untagged traffic coming from the VMware ESXI host?
Refer to the exhibit.
You are validating a Nimble HF40 configuration created in OCA, and you receive an error when you run a CLIC check.
Which Nimble component needs to be added to the configuration to complete the solution?
A customer needs to update a server’s firmware using the latest Support Pack for ProLiant (SPP). They use a bootable USB flash drive to do so, and they select Interactive Mode on boot. Once the device boots, they are unsure how to proceed and ask for your assistance.
What can you tell them to do to easily update the firmware?
You have completed a non-disruptive activation of firmware on an SN6000 switch.
Which session must be restarted manually?
You are installing an HPE ProLiant server in a rack at a customer site. The customer’s facility is in a high-voltage utility service area, and they want to be certain that the power supply is supported.
Which ProLiant feature addresses the customer’s concern?
A customer requires an entry-level, all-flash storage system with predictable performance at the lowest possible price. They have performance-sensitive workloads that require speed and efficiency.
Which HPE storage system meets the customer’s requirements?
A Nimble storage customer is experiencing rapid data growth and needs to scale their storage resources.
Which action should the customer take first?
A customer needs to deploy an application on a newly-installed HPE ProLiant server, but they report that the server is not online. They call you for remote support. The IP address on the production network cannot be reached. You are evaluating the probable root causes of this issue.
According to the troubleshooting methodology, what are next two steps? (Select two)
A customer needs to integrate a new digital video surveillance solution into their existing environment and available network ports. The solution needs to include redundant hypervisor servers and a redundant SAN with a shared Fibre Channel attached storage array.
You plan to propose the following configuration:
What must be added to the configuration to provide a complete solution? (Choose two.)
A customer has a single ProLiant DL560 Gen 10 running a virtualization system. They want to validate installed firmware components at the hardware level.
Which built-in management tool should they use to complete this task?
A customer needs to consolidate software, hardware, and backup in a single integrated solution to reduce the cost and complexity of their IT environment
Which solution meets the customer needs?
A customer needs a solution for a rack of servers. They need connectivity for 14 HPE DL380 servers, which each have two 10-GBASE-T Ethernet ports, and 10 HPE DL360 servers, which have two 10GBASE-X SFP+ Ethernet ports.
They need switch redundancy for each server and want to connect all servers to the same switch stack. The client also needs a 400 Gb backbone connection to the data center core switch from the solution you are creating.
Which architecture meets the customer requirements?
A customer acquires an HPE 3PAR Storeserv 8200 Solution for a data center environment with the following configuration:
After installation and configuration, the storage is put in production. When tiering with the Adaptive Optimization SW is being performed, the customer encountered performance differential issue.
What could be the cause of this issue?
Which protocol verifies that the ports in common between two switches have compatible settings and removes the likelihood of a misconfigured aggregated link?
You need to review a warning on a Nimble storage array.
Click on the menu option that displays this information.
A customer needs to share files among their Microsoft Windows servers cost-effectively and requires disaster support Which native StoreEasy features win address the customer's need? (select two)
recovery
A customer needs to implement VMware across a few racks of servers. They anticipate a large amount of VM creation and retirement.
What are key technologies in a Top of Rack (ToR) switch that support this environment? (Choose three.)
You are troubleshooting a HPE ProLiant rack-mount server. You notice that all front-panel status LEDs flash simultaneously.
What does this indicate has occurred on the server?
A customer needs to improve throughput performance of iSCSI traffic on their Layer 2 switch. Which feature should the customer implement at the switch level?
You are working in a data center with multiple servers and need to update the iLO 5 user names and passwords on a regular basis.
Which tool enables you to streamline and automate this process?
You are troubleshooting an HPE ProLiant rack-mount server. You need to collect event data from the server, even when it is not operational.
Which tool should you use?
A customer needs to virtualize their storage across physical servers and storage environments.
Which HPE solution meets the customer’s needs?
You are installing a server solution in a customer’s data center.
How can you ensure that the installation complies with relevant electrical best practices? (Choose two.)
A customer needs a storage to run a database in an environment with many virtual machines. You have recommended a HPE MSA 2042 solution, but the customer has reservations about whether the MSA 2042 can deliver the required performance.
Which feature of MSA 2042 will help to improve iOP performance?
Place the components on the left in the correct order on the right for the recommended power-up sequence.
A customer is planning an upgrade to their network infrastructure. They want to move to an open networking solution, and they want to install a network switch that supports their choice of network operating system.
Which HPE product family will meet the customer’s needs?
While troubleshooting a HPE ProLiant Gen10 rack-mount server, you determine that the current and backup system ROMs are corrupt.
What should be the next step to fix the server?
You are installing a data center switch.
Which methods are recommended to configure the switch? (Choose two.)
A server administrator needs to see the 24-hour history of the power consumed by an installed HPE ProLiant server.
Which HPE tool can the admin use to gather this information?
A customer has reported that while running an application that is streaming live data, they experience fluctuations in processor frequency as they increase the server performance.
Which HPE ProLiant Gen10 system tuning feature would help eliminate this issue?
You are troubleshooting a HPE ProLiant Gen 9 server and need to find a consolidated view of all the system health and configuration information in a single web interface.
Which HPE tool should you use?
You are installing HPE ProLiant servers into a rack that will be fully loaded. You also need to install four power distribution units (PDUs) in the rack.
How should you install the PDUs to maximize power distribution and space efficiency?