Labour Day Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

HPE6-A66 Sample Questions Answers

Questions 4

Which feature does the Aruba AP 387 support?

Options:

A.

802.11 ax

B.

Indoor usage

C.

included external directional antennas

D.

60GHZRF

Buy Now
Questions 5

A company is redesigning their wireless network and will be upgrading all devices to support the latest wireless standards. The company is not near any radar installations. In order to keep wireless NIC power levels as low as possible to reduce interference issues and to take advantage of radar frequency ranges, what IEEE standard should APs support?

Options:

A.

802.11r

B.

802.11 ax

C.

S02.11V

D.

S02.11h

Buy Now
Questions 6

A network architect is given the task to design a new network solution for NewStellar Company, Inc. NewSteiiar has a main corporate campus in a business park with two adjacent buildings. The network architect has given one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.

Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. Each floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet {870 square meters).

Because of security concerns, video cameras will be installed throughout the facility. There are 16 of these per floor, 8 per wiring closet. The cameras are non-WiFi capable and require POE 802.3af-capable switch ports from which to draw power.

A wireless capacity design is required. Assuming that wireless coverage is required across the Building 1, Floor 2, including the central area, and that half the required APs will connect to each wiring closet, approximately how many POE+ ports will be required per wiring closet for all devices that have POE or POE+ needs?

Options:

A.

30

B.

22

C.

42

D.

8

Buy Now
Questions 7

A company has chosen an Aruba mobility controller solution for the redesign of their wireless network The design will have two 7205 controllers in a cluster for campus employees and a single VMC-50 virtual controller for remote access via a DMZ. A Mobility Master (MM) is used for centralized license and controller management. All controllers will minimally run ArubaOS 8 4 or later Currently the company has 1.000 employees. There are 30 branch offices that will use RAPs to connect to the DMZ controller. A peak of 100 users concurrently using the VIA client will also connect to the DMZ controller.

How many Aruba LIC-VIA licenses does the company need to purchase for this solution?

Options:

A.

100

B.

1

C.

1,030

D.

130

Buy Now
Questions 8

A customer currently has sets of three Aruba 5406R switches deployed for an access layer in multiple wiring closets in a building They are clustered in a VSF domain The customer wants to set up Multiple Active Detection (MAD) for the OOBM port, as well as use this port for remote management access. To simplify the connectivity, the customer wants to connect these three switches' OOBM ports to a separate switch in the wiring closet for the OOBM connectivity.

Which would be the most cost-effective solution that would meet the customer's requirements?

Options:

A.

2530

B.

5406R

C.

2930F

D.

2930M

Buy Now
Questions 9

A network architect is doing a site survey for a new wireless design One concern the company has with the old wireless network is coverage. In some cases, APs would lose power and some employees in the network would lose wireless connectivity. The new design needs to prevent this issue from occurring. During the site survey, what are best practices to be followed in regards to the dBm signal level and the power of the AP to ensure adequate wireless coverage and minimal overlap of AP signals for the new design?

Options:

A.

AP power at 75% and a measurement of -90 dBM on the measuring device

B.

AP power at 100% and a measurement of -65 dBM on the measuring device

C.

AP power at 75% and a measurement of -80 dBM on the measuring device

D.

AP power at 50% and a measurement of -65 dBM on the measuring device

Buy Now
Exam Code: HPE6-A66
Exam Name: Aruba Certified Design Associate Exam
Last Update: Apr 24, 2024
Questions: 60
$64  $159.99
$48  $119.99
$40  $99.99
buy now HPE6-A66