RCDD-002 Sample Questions Answers

Questions 4

The electromagnetic spectrum of visible light lies in the ___________ frequency range of the spectrum.

Options:

A.

1 GHz

B.

100 GHz

C.

10 THz

D.

1 PHz

E.

100 PHz

Buy Now
Questions 5

A common mode (CM) signal can be converted to a differential mode (DM) signal as a result of a(n):

Options:

A.

Unbalanced circuit

B.

Grounded circuit

C.

Poorly timed signal

D.

Improper dielectric material

Buy Now
Questions 6

Where backbone cabling exceeds cabling lengths for the same performance or design (for product used in horizontal cabling), there are three fundamental tests which should be considered when testing. They are:

Options:

A.

Insertion loss (attenuation), return loss, and wiremap/strand identification

B.

Insertion loss (attenuation), return loss, and continuity

C.

Insertion loss (attenuation), return loss, and length

D.

Insertion loss (attenuation), continuity, and wiremap/strand identification

E.

Continuity, wiremap/strand identification, and propagation delay/delay skew

Buy Now
Questions 7

You are preparing to test newly installed open office cabling. Within the open office cabling, there are multiple consolidation points (CP) that were installed while waiting for furniture. How do you proceed with permanent link testing?

Options:

A.

Test to each CP, then test from CP to workstation.

B.

Wait for open office cabling to be completed, then test to each workstation outlet, including the CP.

C.

Test that the CP is within 90 meters, then test again to the workstation outlet.

D.

Perform permanent link tests to each CP, then continuity tests from CP to each workstation outlet.

E.

Test to each workstation outlet, treating each outlet as a channel.

Buy Now
Questions 8

Which of the following covers lightning protection systems and defines as exposed anything above ground and outside the zone of protection?

Options:

A.

NTSB-12

B.

IEEE 1100

C.

NFPA 780

D.

NEC 47

E.

ANSI J/STD-607-A

Buy Now
Questions 9

Which type of cable tray is best described as a ventilated bottom with side rails?

Options:

A.

Ventilated channel

B.

Ladder

C.

Spline

D.

Ventilated trough

E.

Basket tray

Buy Now
Questions 10

The standard floor space coverage area for each building automation system (BAS) is a BAS outlet or device for every ________ of floor space.

Options:

A.

9.3 sq m (100 sq ft)

B.

23 sq m (250 sq ft)

C.

31 sq m (330 sq ft)

D.

56 sq m (600 sq ft)

E.

84 sq m (904 sq ft)

Buy Now
Questions 11

An existing ceiling raceway system has 115,000 sq mm (177 sq in) of cross-sectional area available for distribution of cable runs. How many can be served by the existing system?

Options:

A.

115

B.

160

C.

177

D.

189

E.

195

Buy Now
Questions 12

What is the testing frequency of a Category 6/Class E cable?

Options:

A.

100 MHz

B.

200 MHz

C.

250 MHz

D.

500 MHz

E.

600 MHz

Buy Now
Questions 13

What is the insertion loss guideline for a multimode mechanical splice?

Options:

A.

0.05 dB

B.

0.1 dB

C.

0.3 dB

D.

0.5 dB

E.

1.0 dB

Buy Now
Questions 14

There are three buildings approximately 400 meters apart and the customer wants to use 10 Gig Ethernet. What fiber should be specified for this application?

Options:

A.

8 - 9 micron singlemode

B.

50 micron multimode

C.

50 micron laser optimized multimode

D.

62.5 micron multimode

Buy Now
Questions 15

What is the expected lumenance value, in watts, of a 200 watt fluorescent lamp after three years?

Options:

A.

120 watts

B.

140 watts

C.

160 watts

D.

180 watts

E.

200 watts

Buy Now
Questions 16

Within a heating ventilation and air conditioning automatic control system, what do the letters DDC stand for?

Options:

A.

Dual division charger

B.

Direct digital control

C.

Diverse duct center

D.

Direct drive cable

E.

Differential diffuser control

Buy Now
Questions 17

Within a commercial office building of 2300 sq m (25000 sq ft), how many building automation system (BAS) devices are required?

Options:

A.

50

B.

75

C.

100

D.

125

E.

150

Buy Now
Questions 18

It is important to keep all underfloor cabling systems very neat and orderly. Cabling systems must be managed to ensure that air flow is not impeded by the height or volume of underfloor cabling. Keeping copper communications cabling properly separated from is one design approach. To resolve this:

Options:

A.

Power cabling should be routed in the space below the floor in either hot or cold aisle

B.

Route the copper cables in the cold aisle and route the power cabling in the hot aisle

C.

Power cabling should be routed in the overhead space

D.

Route the copper cables in the hot aisle and route the power cabling in the cold aisle

E.

Copper cabling can be routed in either hot or cold aisles without any consequence in performance of the network

Buy Now
Questions 19

You are designing a cabling containment system installed overhead in a new data center. The main or prime purpose of the system will be to manage fiber optic cabling between cabinets. You have a choice of designs of the containment system. In view of the prime purpose of containment system, your first choice of design will be one that:

Options:

A.

Has a bottom design with a web spacing of less than 203 mm (8 in)

B.

Has a bottom design with a web spacing of less than 152 mm (6 in)

C.

Is manufactured with a soft cloth type material

D.

Has a solid bottom design

E.

The design is not important as long as the client pre approves the manufacturer

Buy Now
Questions 20

What type of redundancy provides two complete units, modules, paths or systems for every one required for a base system.

Options:

A.

N

B.

N+1

C.

N+2

D.

2N

E.

2(N+1)

Buy Now
Questions 21

What is the MINIMUM clearance needed between the front of the telephone booth and any wall or fixture for most installations?

Options:

A.

300 mm (12 in)

B.

450 mm (18 in)

C.

610 mm (24 in)

D.

914 mm (36 in)

E.

2.4 m (8 ft)

Buy Now
Questions 22

Exhibit:

A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (Americans with Disability Act) requirement for side reach using a wheelchair. What will be the maximum reachable height or the value of "X"?

Options:

A.

760 mm (30 in)

B.

864 mm (34 in)

C.

1170 mm (46 in)

D.

1220 mm (48 in)

E.

1370 mm (54 in)

Buy Now
Questions 23

Exhibit:

A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (American with Disabilities Act) requirement for front reach using a wheelchair. What will be the maximum reachable height or the value of "X"?

Options:

A.

760 mm (30 in)

B.

864 mm (34 in)

C.

1170 mm (46 in)

D.

1220 mm (48 in)

E.

1370 mm (54 in)

Buy Now
Questions 24

Which of the following is NOT provided by the ac grounding electrode system?

Options:

A.

Zero volt reference for AC power

B.

A path for dissipating electrical current

C.

A path for dissipating electrostatic discharge

D.

Adequate electrical protection for people and equipment

Buy Now
Questions 25

The recommended MAXIMUM value for the bonding resistance between the nearest available grounding electrode and the busbar in an entrance facility (EF) is ________ ohms.

Options:

A.

0.1

B.

0.5

C.

1

D.

2

E.

5

Buy Now
Questions 26

What is the MINIMUM ceiling height of a telecommunications room?

Options:

A.

2.1 m (7.0 ft)

B.

2.3 m (7.5 ft)

C.

2.4 m (8.0 ft)

D.

2.6 m (8.5 ft)

E.

2.7 m (9.0 ft)

Buy Now
Questions 27

In a telecommunication room (TR), the ________ is the facility used to make cross connections from the backbone cable to the horizontal cable.

Options:

A.

Horizontal cross-connect (HC)

B.

Entrance facility (EF)

C.

Intermediate cross-connect (IC)

D.

Main cross-connect (MC)

Buy Now
Questions 28

Which of the following types of conduit uses set screw couplings and connectors?

Options:

A.

RMC

B.

EMT

C.

IMC

D.

Schedule 80 PVC

Buy Now
Questions 29

Which of the following is NOT true about consolidation points?

Options:

A.

They are not to be used for direct connections to active equipment.

B.

They allow horizontal cables to be extended into work area pathways.

C.

They are to be terminated on separate connectors for each individual user.

D.

The maximum length of cable from the consolidation point (CP) to the outlet varies by media type.

Buy Now
Questions 30

Which of the following is NOT a type of connector for optical fiber?

Options:

A.

LC

B.

ST

C.

SFF

D.

S/FTP

E.

SC

Buy Now
Questions 31

A furniture cluster with 26 requires a MINIMUM of how many multiuser telecommunications outlet assembly (MUTOA)?

Options:

A.

1

B.

2

C.

3

D.

4

E.

5

Buy Now
Questions 32

Aerial entrances to small buildings should be limited to ________ cable pair or less.

Options:

A.

6

B.

12

C.

25

D.

50

E.

100

Buy Now
Questions 33

Which one of the following is NOT an advantage of direct-buried cable?

Options:

A.

Is flexible for future reinforcements or changes

B.

Has a low initial installation cost

C.

Can easily bypass obstructions

D.

Preserves the aesthetic appearance of buildings

Buy Now
Questions 34

The information technology system (ITS) designer should design conduits entering a building from below grade point to extend ________ above finished floor (AFF).

Options:

A.

51 mm (2 in)

B.

100 mm (4 in)

C.

152 mm (6 in)

D.

203 mm (8 in)

E.

254 mm (10 in)

Buy Now
Questions 35

Color codes for cross-connection fields have been used for many years. Which color is used to identify network connections?

Options:

A.

Green

B.

Orange

C.

Purple

D.

Yellow

E.

Brown

Buy Now
Questions 36

Which class of the system applies when the premise only has a single equipment room (ER), and it is the only telecommunications space administered?

Options:

A.

Class 1

B.

Class 2

C.

Class 3

D.

Class 4

Buy Now
Questions 37

In an industry where a high level of humidity is measured, which type of label should be used?

Options:

A.

Moisture-induced decay and degradation resistant

B.

Ultraviolet (UV) light protected

C.

Heat and cold resistant

D.

Smudge resistant

E.

Chemical resistant

Buy Now
Questions 38

The average power consumption in a telecommunications room (TR) is 2260 watts per hour. What is the heat dissipation in BTUs?

Options:

A.

7096 BTU

B.

7713 BTU

C.

8104 BTU

D.

8511 BTU

Buy Now
Questions 39

The formula for calculating BTUs from electrical power is:

Options:

A.

W x 0.707

B.

W x 1.732

C.

W x 3.1416

D.

W x 3.413

Buy Now
Questions 40

You are designing a large equipment room (ER) that will house many servers, switches, backup storage drives, and other communications equipment including peripheral devices. To prevent problems from harmonic currents that can be created by switching power supplies, you should arrange for:

Options:

A.

Isolated grounding

B.

Oversized neutral and grounding conductors

C.

Surge protection on power supply

D.

A 3-phase feeder supply separate from the building supply

E.

Power filtering at the service panel

Buy Now
Questions 41

What is the appropriate impedance of coaxial cable for use with broadband distribution?

Options:

A.

50

B.

75

C.

100

D.

150

Buy Now
Questions 42

Exhibit:

The following diagram indicates what type of CATV distribution system?

Options:

A.

Trunk and tap

B.

Video over balanced twisted-pair

C.

Video over optical fiber

D.

Home run

Buy Now
Questions 43

A building has a series of CATV outlets each with cables installed back to a telecommunications room (TR), and each telecommunications room (TR) is connected to the headend. What is this type of topology called?

Options:

A.

Star

B.

Mesh

C.

Bus

D.

Series

Buy Now
Questions 44

You are designing the cabling infrastructure for a lab office building that will frequently change tenants. The owner will be responsible for all of the infrastructure that feeds each floor to include the telecommunication rooms. Which firestop method will best suit the owners needs?

Options:

A.

Cable transit system

B.

Factory fabricated sleeve system

C.

Firestop pillow system

D.

Silicone foam system

Buy Now
Questions 45

Most types of firestop putty have ________ properties.

Options:

A.

Water based

B.

Cementitious

C.

Intumescent

D.

Silicone based

Buy Now
Questions 46

A(n) ________ system is considered a mechanical firestop.

Options:

A.

Cementitious

B.

Cable transit

C.

Firestop block

D.

Intumescent sheet

Buy Now
Questions 47

Geographically speaking, a __________ covers an area associated with an individual's work space.

Options:

A.

SAN

B.

PAN

C.

LAN

D.

CAN

E.

WAN

Buy Now
Questions 48

You have just assumed management responsibility over an older network consisting of passive hubs and some layer 2 switches. The network is experiencing massive slow downs on an irregular basis. Which of the following is the MOST effective immediate solution to the problem?

Options:

A.

Purchase and install layer 3 switching equipment.

B.

Purchase and install a software based gateway.

C.

Add bridges at key points in the network.

D.

Segment your network into smaller domains.

Buy Now
Questions 49

IPv-4 addresses are ________ bits in length.

Options:

A.

16

B.

24

C.

32

D.

48

E.

64

Buy Now
Questions 50

Premises optical fiber links should be tested:

Options:

A.

In one direction at one corresponding wavelength

B.

In one direction at both corresponding wavelengths

C.

Bidirectionally at one corresponding wavelength

D.

Bidirectionally at both corresponding wavelengths

Buy Now
Questions 51

A security program consists of three independent components. They are electronic, architectural, and:

Options:

A.

Operational

B.

Physical

C.

Environmental

D.

Elemental

Buy Now
Questions 52

You have been asked to project manage a fiber cable backbone installation. In the course of the installation, you notice the fiber cable with a 25 mm (1 in) outside diameter is being installed into a small TR, and the cable is being installed into a tight corner. Based on your knowledge of minimum bend radius requirements for fiber cable, you must ensure that the MINIMUM cable bend radius of _______________ is provided when the cable installation is completed.

Options:

A.

254 mm (10 in)

B.

305 mm (12 in)

C.

381 mm (15 in)

D.

457 mm (18 in)

E.

610 mm (24 in)

Buy Now
Questions 53

Which of the following statements best describes what a backbone distribution system typically provides?

Options:

A.

Cabling from the HC to the WA

B.

Pathway from the HC to the WA

C.

Conduit in a building riser

D.

Building connections between floors in a multistory building

E.

Copper cabling installed in a large building

Buy Now
Questions 54

The decision regarding the number of optical fibers to install (fiber strand count) in a backbone depends largely on all of the following EXCEPT:

Options:

A.

Level of multiplexing

B.

Intended end-user applications

C.

Physical topology of the cabling system

D.

Distance between telecommunications room (TR)

E.

Cabling system configuration

Buy Now