Summer Sale - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65percent

Welcome To DumpsPedia

D-PE-OE-01 Sample Questions Answers

Questions 4

During a physical Inspection, the System Status LED Is blinking blue. What does this indicate?

Options:

A.

Hardware fault detected

B.

PSU redundancy lost

C.

Thermal threshold exceeded

D.

System is being identified

Buy Now
Questions 5

A technician In Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams. What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC?

Options:

A.

Client IP address

B.

CHAP authentication credentials

C.

Share name

D.

Username and password

Buy Now
Questions 6

You are assisting an administrator, who Is working on a PowerEdge R670. They are trying to connect to iDRAC using iDRAC Direct but cannot make a connection. The LED status indicators are: the wrench/spanner LED on the front right is off, the system ID LED on the front right is blinking blue, and the power LED on the front right is amber. What action should be taken to establish connectivity?

Options:

A.

Press the power button once

B.

Press and hold the system ID button for 5-10 seconds

C.

Press the system ID button once

D.

Press and hold the power button for 5-10 seconds

Buy Now
Questions 7

A Dell PowerEdge server reports intermittent hardware alerts and occasional system instability. An administrator needs to Identify and resolve the underlying hardware Issue with minimal disruption to services. Which action should the administrator take first to troubleshoot the hardware problem?

Options:

A.

Use iDRAC to review hardware health status and the SEL

B.

Disable monitoring alerts to prevent false warnings

C.

Reinstall the operating system to eliminate software-related causes

D.

Replace multiple hardware components simultaneously

Buy Now
Questions 8

On a Dell PowerEdge 16G server, iDRAC is configured to use a shared LOM port. What happens if the Auto-Dedicated NIC option is enabled and a dedicated NIC becomes available?

Options:

A.

iDRAC uses both the shared LOM and dedicated NIC simultaneously for redundancy

B.

iDRAC automatically switches to the dedicated NIC without requiring a reboot

C.

iDRAC disables network connectivity until manually reconfigured

D.

iDRAC continues using the shared LOM port until the next reboot

Buy Now
Questions 9

Your customer requires a way to monitor a high-level and holistic view of the workload of their servers. A database server was identified as providing lower than expected performance after migrating to a PowerEdge R760 server. Which option can be selected in iDRAC to monitor this level of information?

Options:

A.

CPU Utilization

B.

I/O Utilization

C.

Memory Utilization

D.

System Level CUPS Index

Buy Now
Questions 10

In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?

Options:

A.

Apply iDRAC Enterprise License

B.

Acquire appropriate Login privilege

C.

Set iDRAC networking to use DHCP

D.

Enable RACADM

Buy Now
Questions 11

A Dell PowerEdge server has Temperature Alert Configuration set up in iDRAC. A Test Event was executed, and email alerts appeared to be delivered successfully. However, a few days later, the server unexpectedly rebooted. Upon inspection, CPU temperatures had exceeded the configured threshold. What is a possible reason IDRAC failed to alert the administrator about the high temperature?

Options:

A.

iDRAC only sends alerts for Critical events or higher.

B.

Although the Temperature Alert was configured, it was not fully activated.

C.

Test Events verify alert delivery but do not trigger actual hardware alerts.

D.

The reboot may have bypassed iDRAC alert mechanisms.

Buy Now
Questions 12

You are asked to perform a quick health check across multiple NVIDIA GPUs in a cluster without impacting running workloads. Which DCGM diagnostic level should be used?

Options:

A.

Level 1

B.

Level 2

C.

Level 3

D.

Level 4

Buy Now
Questions 13

You are performing a GPU firmware update using IDRAC. IDRAC Direct was used during the update. The update stalls and the GPU appear unresponsive. What is the most likely cause of the issue?

Options:

A.

The server needs a BIOS downgrade

B.

The USB management port interaction

C.

The iDRAC license expired during the update

D.

The GPU is incompatible with the server OS

Buy Now
Questions 14

A PowerEdge R760 powers on with no video output. You decide to perform a Minimum-to-POST test. Which configuration correctly represents a valid Minimum-to-POST?

Options:

A.

One CPU with all associated DIMM, one PSU, no PCIe card

B.

One CPU, one DIMM in the primary channel, one PSU, no PCIe card

C.

Two CPUs installed with all DIMMs populated, one PCIe card

D.

One CPU with all associated DIMM, one PSU, one PCIe card

Buy Now
Questions 15

After adding DIMMs on a PowerEdge R760, the server powers on, fans spin, but the system does not reach POST. The LCD shows no error. What two things should be done to resolve this Issue?

Options:

A.

Reseat memory

B.

Replace the system board

C.

Verify DIMM population

D.

Update the BIOS

E.

Clear SEL logs

Buy Now
Exam Code: D-PE-OE-01
Exam Name: Dell PowerEdge Operate v2 Exam
Last Update: Jul 26, 2026
Questions: 50

PDF + Testing Engine

$59.99 $171.4

Testing Engine

$44.99 $128.55

PDF (Q&A)

$49.99 $142.82