2022 New Year Express Limited Time 55% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 5763r953

Welcome To DumpsPedia

DES-1241 Sample Questions Answers

Questions 4

What is the last step when adding a drive to a Dell EMC PowerStore system?

Options:

A.

Verify the new drive is seen

B.

Add the drive to the pool

C.

Backup the keystore

D.

Zero the drive

Buy Now
Questions 5

What does the output of the PSTCLI command “nas_server show” display from a Dell EMC PowerStore T?

Options:

A.

If NAS servers are present if they are either NFS or Licensed

B.

Memory utilization and thread count for NFS NAS servers

C.

If NAS servers are present and if they are either Started or Degraded

D.

SIDs of SMB NAS servers joined to the AD Domain

Buy Now
Questions 6

A Storage Administrator is adding an appliance into an existing Dell EMC PowerStore T cluster.

What is different about the management network configuration for the new appliance compared to configuring an initial appliance for the cluster?

Options:

A.

All the needed management IP addresses for the new appliance must be pre-configured on the cluster

B.

Additional appliance does not require a cluster management IP address

C.

Additional appliance inherits all its management IPs from the existing appliance

D.

All the needed management IP addresses for the new appliance are auto-generated by the cluster

Buy Now
Questions 7

Which Dell EMC PowerStore model reserves the last two slots of the base enclosure for NVMe NVRAM?

Options:

A.

3000

B.

5000

C.

7000

D.

9000

Buy Now
Questions 8

A Storage Administrator needs root access. What command needs to be run?

Options:

A.

svc_inject generate-key --root

B.

svc_inject -root

C.

sudo service

D.

su - root

Buy Now
Questions 9

What is the default log collection schedule?

Options:

A.

Weekly

B.

As scheduled during install

C.

Hourly

D.

Daily

Buy Now
Questions 10

Order the NDU operational steps.

Options:

Buy Now
Questions 11

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in troubleshooting the problem?

Options:

A.

Select the Gather Support Materials from Service and Support

B.

Access the Repair Flow link to schedule a support engagement

C.

Examine Notifications to obtain a list of corrective actions

D.

Re-engage support through previous listed Related Events

Buy Now
Questions 12

A Storage Administrator notices two fans in a Dell EMC PowerStore are faulted. What describes the system behavior in this circumstance?

Options:

A.

A five-minute timer starts upon the second fan fault and the system shuts down automatically after the timer expires

B.

CPU clock speed is reduced by 50% to lower internal temperatures and the system continues normal operations

C.

An increased fan speed signal is sent to the surviving fans and the system continues normal operations

D.

Upon the second fan fault, all host I/O is terminated immediately and the PowerStore goes through the halt and vault process and shuts down

Buy Now
Questions 13

During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

Options:

A.

Reboot node B

B.

Clear the boot mode

C.

Disable node B boot mode

D.

Return node A to normal mode

Buy Now
Questions 14

In an unpopulated rack, at what U mark is the base enclosure racked?

Options:

A.

3

B.

4

C.

2

D.

1

Buy Now
Exam Code: DES-1241
Exam Name: Specialist - Platform Engineer PowerStore Exam
Last Update: Jan 20, 2022
Questions: 96
$72  $159.99
$54  $119.99
$45  $99.99
buy now DES-1241