Questions 4

The dynamic environment monitoring system can be deployed in medium and large modular data centers, small modular data centers, container data centers, etc.

Options:

A.

True

B.

False

Buy Now
Questions 5

Exist UPS in the system, the most comprehensive description of the role of the inverter circuit is ____________ .

Options:

Buy Now
Questions 6

PLE Defined as the power consumption of the data center power supply and distribution system and IT The ratio of the power consumption of the device.

Options:

A.

True

B.

False

Buy Now
Questions 7

The condensate of the air conditioner is formed by condensation after the air warning surface cooler cools down.

Options:

A.

True

B.

False

Buy Now
Questions 8

The user can use the ____________ function to assign personnel to handle the fault.

Options:

Buy Now
Questions 9

ATS The dual power supply automatic switch can realize the fast mechanical switching of the two power supplies.

Options:

A.

True

B.

False

Buy Now
Questions 10

Huawei Monitoring System NetEco Must not support monitoring of third-party devices.

Options:

A.

True

B.

False

Buy Now
Questions 11

The device cannot be connected to the southbound interface of the dynamic environment monitoring system.

Options:

A.

Precision air conditioner

B.

UPS

C.

Access control equipment

D.

Upper-level network management

Buy Now
Questions 12

Reflects the dryness of the air, the smaller the value, the drier the air.

Options:

A.

Moisture content

B.

Wet bulb temperature

C.

Relative humidity

D.

Dry bulb temperature

Buy Now
Questions 13

The possible functions of the dynamic loop monitoring system include ____________ .

Options:

Buy Now
Questions 14

UPS It can purify the mains input, output stable AC, and protect the load.

Options:

A.

True

B.

False

Buy Now
Questions 15

During the construction process, if there is an object falling or hitting, it should be used ____________ .

Options:

Buy Now
Questions 16

The gas fire extinguishing system consists of ____________ .

Options:

Buy Now
Questions 17

At the end of the discharge of lead-acid batteries, the voltage drops, and the positive and negative active materials are converted into ____________ .

Options:

Buy Now
Questions 18

Huawei Monitoring System NetEco Support through ____________, send alarm information to customers.

Options:

Buy Now
Questions 19

The function of the air system is to rationally organize the flow of indoor air, so that the temperature, humidity and cleanliness of the air in the indoor working area can better meet the process requirements and the comfort requirements of the human body.

Options:

A.

True

B.

False

Buy Now
Questions 20

The components of Huawei's dynamic environment monitoring system are ____________ .

Options:

Buy Now
Questions 21

During the construction process, work in contact with sharp instruments and use ____________ .

Options:

Buy Now
Questions 22

Huawei Monitoring System NETECO Supported functions are ____________ .

Options:

Buy Now
Questions 23

For valve-regulated lead-acid batteries, the function of the safety valve is ____________ .

Options:

Buy Now
Questions 24

In the main inverter mode, when the mains input voltage and frequency exceed ups When the allowable range isups Will be inverted from the main circuit. The mode shifts to static bypass mode.

Options:

A.

True

B.

False

Buy Now
Questions 25

The administrator cannot segment the login time and login of other users through the Huawei monitoring system IP Address restrictions.

Options:

A.

True

B.

False

Buy Now
Questions 26

CLF Defined as the power consumption of data center cooling equipment and IT The ratio of the power consumption of the device.

Options:

A.

True

B.

False

Buy Now
Questions 27

CLF Defined as the power consumption of data center cooling equipment and IT The ratio of equipment power consumption.

Options:

A.

True

B.

False

Buy Now
Questions 28

The humidifier used in Huawei's row-level precision air conditioner is an infrared humidifier.

Options:

A.

True

B.

False

Buy Now
Questions 29

STS The static transfer switch can switch between different input power sources and provide dual power supply for single power loads.

Options:

A.

True

B.

False

Buy Now
Questions 30

The alarms of the dynamic environment monitoring system usually have different levels.

Options:

A.

True

B.

False

Buy Now