Easter Special Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

Hybrid-Cloud-Observability-Network-Monitoring Sample Questions Answers

Questions 4

Which two of the following locations can hardware health be enabled? (Choose two.)

Options:

A.

asset inventory

B.

list resources

C.

main settings

D.

manage MIB

Buy Now
Questions 5

Which status rollup mode displays groups defined as collections of redundant or backup devices?

Options:

A.

show best

B.

show mixed

C.

show worst

D.

showzero

Buy Now
Questions 6

Which SNMP version will support MD5, SHA1, SHA256, and SHA512 authentication in SolarWinds’ platform?

Options:

A.

version 1

B.

version 2

C.

version 2c

D.

version 3

Buy Now
Questions 7

Probing interval determines how often and how long information is polled from the network path. Which two of the following statements are true regarding probing intervals? (Choose two.)

Options:

A.

probing less frequently allows the data to update more slowly and increases data accuracy

B.

probing less frequently allows the data to update faster but decreases data accuracy

C.

probing more frequently allows the data to update faster but decreases data accuracy

D.

probing more frequently allows the data to update more slowly and increases data accuracy

Buy Now
Questions 8

A probe is to be built to test connections to Office 365 from two different locations. How would this be accomplished?

Options:

A.

Create a probe, duplicate it, and change the source agent to the agent in another location.

B.

Create both probes on hybrid cloud observability (HCO) server and designate each location.

C.

Create two probes and assign each to an agent in each location.

D.

Create two probes and assign each to an agent in one location.

Buy Now
Questions 9

Which three of the following flow protocols does hybrid cloud observability support? (Choose three.)

Options:

A.

J-Flow

B.

NetFlowv6

C.

NetFlowv9

D.

sFlow

Buy Now
Questions 10

A network router node using ICMP polling has a green status icon and shows basic information (i.e., status) but is not showing more detailed statistics. What might resolve this issue?

Options:

A.

Edit the node properties to verily proper polling credentials.

B.

Run ping tests to verily communication.

C.

Switch polling to SNMP to gather additional polling statistics.

D.

Unmanage and re-manage the node.

Buy Now
Questions 11

In live mode, how frequently is log viewer data automatically refreshed?

Options:

A.

1 second

B.

10 seconds

C.

1 minute

D.

10 minutes

Buy Now
Questions 12

An existing NetPath probe is examined, and it is noted that the thickness of connection lines is different on various routes between devices. What does this indicate?

Options:

A.

The probing interval for the probe is shorter on one path than on the other.

B.

The thicker line indicates the more likely path of traffic from source to destination.

C.

The thicker line is monitored in hybrid cloud observability (HCO) and contains other metrics.

D Two probes with different probing intervals are monitoring the same path

Buy Now
Questions 13

Flow data is not generating from a device in the web console. Wireshark was used to confirm the flows are being sent from the device to the poller and not blocked by the firewall. Why is the data not showing in the web console?

Options:

A.

device is not monitored by hybrid cloud observability (HCO) features

B.

device is using IPv6 and HCO only supports IPv4

C.

missing source address field in flow configurations

D.

flow monitoring was not enabled as device type in web console settings

Buy Now
Questions 14

If the data collected for hardware health is incorrect, which step could rectify the issue?

Options:

A.

Change the MIB tree used for polling.

B.

Change the poller assigned to sensor.

C.

Create a custom goller in device studio for fan speed, power supply, and temperature.

D.

Download the MIB file from the SolarWinds website and add it to the device's firmware.

Buy Now
Questions 15

What is the unit of data used for alerting on flows?

Options:

A.

bPs

B.

gps

C.

mbps

D.

ms

Buy Now
Questions 16

Which two of the following functions are tied to SolarWinds’ MIB database? (Choose two.)

Options:

A.

SolarWinds’ MIB database defines what kind of pollers can be built for the metric.

B.

SolarWinds’ MIB database enables automatic polling of devices.

C.

SolarWinds’ MIB database maps object IDs (OIDs) to their textual names.

D.

aSolarWinds’ MIB database updates OIDs on the device during the polling process.

Buy Now
Questions 17

Which two of the following actions can be taken to resolve unknown flow traffic events? (Choose two.)

Options:

A.

Add the devices and interfaces to SolarWinds' database.

B.

Configure devices to send all flow data.

C.

Enable automatic addition of flow sources.

D.

Ensure flow-enabled devices send data to appropriate port.

Buy Now
Questions 18

Which custom poller can display the poller results as a chart, gauge, or table?

Options:

A.

device studio poller

B.

hardware health

C.

network insight

D.

universal device poller (UnDP)

Buy Now
Questions 19

Which additional polling method is needed after adding Cisco ASA and Cisco Nexus for SNMP monitoring?

Options:

A.

API

B.

ICLI

C.

Control

D.

WMI

Buy Now
Questions 20

In which two of the following cases does duplicate flow data occur? (Choose two.)

Options:

A.

both IP flow ingress and egress applied for all interfaces

B.

both IP flow ingress and egress applied on one interface

C.

IP flow ingress applied on all interfaces, no egress usage

D.

IP flow ingress on some interfaces and egress on others

Buy Now
Questions 21

Which two of the following technologies does device studio support? (Choose two.)

Options:

A.

baseline and thresholds

B.

|multi-CPU and memory

C.

node details

D.

throughput

Buy Now
Questions 22

Which tool in the web console will verify the object ID (OID) being used is a match for the node being created for a custom poller?

Options:

A.

CLI settings

B.

component library

C.

firmware repository

D.

MIB browser

Buy Now
Questions 23

In which scenario would the device studio poller tool be considered the best tool for building a required poller?

Options:

A.

Building a poller for ARP tables to display in the web console.

B.

Building a poller to add missing information to node details.

C.

Building a poller to monitor VPN tunnel status.

D.

Building a poller to show CPU and memory status.

Buy Now
Questions 24

Which statement related to flow alerts is true?

Options:

A.

based on custom SQL query

B.

can be triggered even when NetFlow service is down

C.

have no trigger actions

D.

object of the alert selected from create a flow alert panel

Buy Now
Questions 25

From which two of the following locations can the status of the flow collector service be checked? (Choose two.)

Options:

A.

flow and CBQoS sources

B.

NetFlow collector services

C.

NetFlow settinqs

D.

top XX receivers

Buy Now
Questions 26

Which two of the following flow technologies are supported? (Choose two.)

Options:

A.

GFlow

B.

HFlow

C.

J-Flow

D.

sFlow

Buy Now
Questions 27

Which statement depicts the relationship between device studio pollers’ supported technologies and universal device pollers’ (UDPs) supported technologies?

Options:

A.

device studio pollers can poll for CPU utilization of SNMP enabled devices, UDPs cannot

B.

device studio pollers can poll for node details of SNMP enabled devices, UDPs cannot

C.

UDPs can poll for hardware status of SNMP enabled devices, device studio pollers cannot

D.

UDPs can poll for memory utilization of SNMP enabled devices, device studio pollers cannot

Buy Now
Questions 28

Several resources are showing duplicate flow data. What is the most likely cause?

Options:

A.

interfaces have duplicate entries in flow sources management

B.

interfaces in flow sources management are set to drop

C.

SolarWinds' NetFlow service needs to be restarted

D.

source devices are configured to export flow data on ingress and egress

Buy Now
Questions 29

SNMP traps are being received from several devices. While most of the traps are normal, traps from one of the devices contain fields that are unreadable. The device is not being monitored in any other way. Which two of the following points should be checked? (Choose two.)

Options:

A.

Verify the device is not usingSNMFV3 and is added as a node.

B.

Verity the device supports hybrid cloud

C.

Verify the device supports SNMP and is added as a node.

D.

Verify the device's MIBfile is in SolarWinds' MIB database.

Buy Now
Questions 30

Which statement is true regarding universal device pollers (UDP)?

Options:

A.

perform operations /transformations on polled data

B.

poll multiple object IDs (QIDs) for a given technology

C.

polled values are displayed in dedicated resources

D.

polled values are displayed in existing resources

Buy Now
Questions 31

Through which means does NetFlow traffic analysis (NTA) process flow data?

Options:

A.

agent

B.

collector

C.

configuration

D.

polling method

Buy Now
Questions 32

On a single node, one or more interfaces are showing an “unknown” status. What is the best way to resolve the issue?

Options:

A.

Change node's pollingmethod to ICMP.

B.

Delete and rediscover the node showing affected interfaces.

C.

Delete and re-add the affected interfaces.

D.

Verify the interfaces are assigned to SolarWinds' native poller.

Buy Now
Questions 33

Which two of the following services can be monitored in network insight with network health, performance monitor, and NCM features installed in hybrid cloud observability? (Choose two.)

Options:

A.

access lists

B.

global protect VPN

C.

high availability details

D.

policy details

Buy Now
Questions 34

A device studio poller is being built for node detail information. For the values supported, it has been decided to enter textual values instead of object IDs (OIDs). Which statements is true?

Options:

A.

If the textual value changes, it will update automatically.

B.

If the textual value changes on the node, the poller must be manually updated.

C.

If the textual value is misspelled, it will not poll correctly.

D.

Only textual values can be used for host names, all other values must be OlDs.

Buy Now
Questions 35

A new node has been added to hybrid cloud observability; however, certain data being polled on similar devices is not being polled on the new node. How can this be resolved?

Options:

A.

assign existinguniversal device poller (UDP) to new node

B.

assign the new node to the same polling engine

C.

UDP must be re-created for new node

D.

verily the credentials for the new node are valid

Buy Now
Questions 36

Which NetFlow component can be applied to an interface to track IPv4 traffic?

Options:

A.

flow exporter

B.

flow monitor

C.

flow record

D.

Iflow sampler

Buy Now
Questions 37

Some of the flows received are mapping to an IP address that does not match any of the nodes being monitored. It has been verified that all flow sources are also being monitored by NPM and SNMP polling. The known source nodes for these flows have the correct IP address. What could be causing this issue?

Options:

A.

flows are coming from a non-primary address and the setting to match the node by another IP is turned off

B.

flows are IPv6 and the network monitoring does not recognize that version

C.

IP address for the node is incorrect in SNMP polling but correct in the flows

D.

source machine field in the flows is not configured and the setting to match the node by another IP is turned off

Buy Now
Questions 38

Which SNMP version allows usernames and passwords?

Options:

A.

version 1

B.

version 2c

C.

version 3

D.

version 4

Buy Now
Questions 39

What is the maximum number of resources that can be displayed in flow charts created by SolarWinds’ platform views?

Options:

A.

25

B.

50

C.

75

D.

100

Buy Now
Questions 40

What is the default amount of historical data needed for calculating capacity forecast?

Options:

A.

1 to 30 days

B.

1 to 90 days

C.

7 to 30 days

D.

7 to 180 day

Buy Now
Questions 41

The fan of a network device has failed; however, the status shows as “up” on the current hardware health resource in the node details view. Which two of the following causes could be creating the issue? (Choose two.)

Options:

A.

hardware sensors are disabled

B.

resource is showing outdated information

C.

threshold of the fan sensor has been forced

D.

wrong MIB being used for polling

Buy Now
Questions 42

Which two of the following statistics are available for network capacity planning? (Choose two.)

Options:

A.

disk space forecast

B.

memory usage data on nodes

C.

node temperature

D.

receive utilization on interfaces

Buy Now
Questions 43

Upon examining bandwidth utilization, it is confirmed that the total utilization and flow numbers do not match. What is the likely cause?

Options:

A.

a firewall is blocking the data flow configuration

B.

flows do not contain all traffic in bandwidth numbers

C.

receivingboth IPv4 and IPv6 flows and not all are counted in total bandwidth

D.

SNMP bandwidth numbers for the interface need to be adjusted in the console

Buy Now
Questions 44

Which additional polling method is needed after adding an F5 load balancing node for SNMP monitoring?

Options:

A.

API

B.

CLI

C.

iControl

D.

WM1

Buy Now
Questions 45

A universal device poller (UDP) and a transformer are built to display a transform value for a node’s CPU temperature, however the value is not transformed as displayed on the web console. Which two of the following reasons could have caused the issue? (Choose two.)

Options:

A.

custom poller used for transformation is not assigned to same node

B.

custom poller and transformer are not using same polling interval

C.

node pollinginterval does not match the custom poller interval

D.

pollinginterval for thecustom poller is usingthe default value

Buy Now
Exam Code: Hybrid-Cloud-Observability-Network-Monitoring
Exam Name: Hybrid Cloud Observability Network Monitoring Exam
Last Update: May 14, 2024
Questions: 151
$64  $159.99
$48  $119.99
$40  $99.99
buy now Hybrid-Cloud-Observability-Network-Monitoring