ITFAS-Level-1 Sample Questions Answers

Questions 4

Which of the following options is required while conducting annual testing of an audiovisual device?

Options:

A.

Confirm sound level based on design

B.

Confirm voice intelligibility

C.

Verify proper operation

D.

Verify proper setting of candela rating

Buy Now
Questions 5

How far away from the center line of the elevator door can a smoke detector be located?

Options:

A.

3 feet (1.0 meter)

B.

5 feet (1.5 meters)

C.

12 feet (3.7 meters)

D.

21 feet (6.4 meters)

Buy Now
Questions 6

An abnormal condition where a system, component, or function is out of order, and the condition can result in the system or unit not functioning when required is called which of the following terms?

Options:

A.

Impairment

B.

Intermittent

C.

Operational

D.

Supervisory

Buy Now
Questions 7

According to NFPA 72, in addition to the type of equipment, which additional factor should be considered when determining the frequency of cleaning system equipment?

Options:

A.

Age of the equipment

B.

Frequency of periodic testing

C.

Local ambient conditions

D.

Number of devices per loop

Buy Now
Questions 8

According to NFPA 72, manual fire alarm boxes shall be located within which distance of each exit doorway on each floor?

Options:

A.

5 feet (1.5 meters)

B.

6 feet (2.0 meters)

C.

16 feet (5.0 meters)

D.

33 feet (10.0 meters)

Buy Now
Questions 9

When testing initiating devices, what is the maximum allowed time for the supervising station to verify receipt of the signal?

Options:

A.

60 seconds

B.

80 seconds

C.

90 seconds

D.

120 seconds

Buy Now
Questions 10

When is the elevator recall permitted to send a supervisory signal in lieu of an alarm signal?

Options:

A.

Where approved by the authority having jurisdiction

B.

Where approved by the building owner

C.

Where approved by the insurance company

D.

Where approved by the system designer

Buy Now
Questions 11

According to NFPA 72, which statement is true as it pertains to the testing of audible alarm notification appliances?

Options:

A.

Sound pressure levels are required to be taken during initial acceptance and periodic testing.

B.

Sound pressure levels are required to be taken during initial acceptance and reacceptance testing.

C.

Sound pressure levels are required to be taken in hallways only during initial acceptance testing.

D.

Sound pressure levels are required to be taken in sleeping areas only during initial acceptance testing.

Buy Now
Questions 12

What is the maximum extended interval allowed for equipment to get inspected?

Options:

A.

3 months

B.

6 months

C.

12 months

D.

18 months

Buy Now
Questions 13

How often should a monitored fire alarm system be inspected for trouble signals?

Options:

A.

Weekly

B.

Monthly

C.

Semiannually

D.

Annually

Buy Now
Questions 14

Inspection records for all systems shall be kept for which length of time?

Options:

A.

6 months

B.

5 years

C.

Until AHJ reviews records and 1 year

D.

Until the next test and 1 year

Buy Now
Questions 15

Which three of the following are how a McCulloh transmitter should be inspected? (Choose three.)

Options:

A.

Distinct waterflow condition

B.

Physical condition

C.

System normal condition

D.

Verify location

Buy Now
Questions 16

Lights used for fire alarm signaling shall be which of the following colors?

Options:

A.

Clear or amber

B.

Clear or blue

C.

Clear or nominal white

D.

Clear or red

Buy Now
Questions 17

What is the adjustment range for smoke detectors that have a provision for field adjustment of sensitivity?

Options:

A.

No less than 0.6% per foot (1.95% per meter)

B.

No more than 0.6% per foot (1.95% per meter)

C.

No more than 1.2% per foot (3.90% per meter)

D.

No less than 1.2% per foot (3.90% per meter)

Buy Now
Questions 18

An off-normal signal shall be initiated during which of the following travel distances of the valve control apparatus from its normal position?

Options:

A.

1/5

B.

1/4

C.

1/3

D.

1/2

Buy Now
Questions 19

When is a shunt trip operated to power down an elevator?

Options:

A.

When a heat detector is tripped

B.

When a pull station is activated

C.

When a smoke detector is tripped

D.

When a sprinkler head is activated

Buy Now
Questions 20

When a system must be fully or partially disabled for less than 8 hours, who must be notified when the system is restored?

Options:

A.

AHJ

B.

Fire department

C.

Insurance company

D.

System owner

Buy Now
Questions 21

How should the documentation cabinet be labeled?

Options:

A.

Fire alarm documents

B.

Fire alarm record documents

C.

System records

D.

System record documents

Buy Now
Questions 22

Smoke detector activation in the ninth-floor elevator lobby shall activate which of the following functions?

Options:

A.

Alternate level recall

B.

Designated level recall

C.

Ninth-floor supervisory signal

D.

Ninth-floor trouble signal

Buy Now
Questions 23

An inspector has been given a list of 45 devices and 1 fire alarm control unit that needs to be inspected at a job site. The inspector knows it takes on average about 2 minutes to inspect 1 device with documentation. Also, the inspector knows it takes 20 minutes to perform the required tests on the fire alarm control unit and get the system restored.

How long does the inspector tell the owner that the fire alarm system is expected to be impaired?

Options:

A.

1 hour, 5 minutes

B.

1 hour, 10 minutes

C.

1 hour, 30 minutes

D.

1 hour, 50 minutes

Buy Now
Questions 24

What is the periodic testing frequency of a control valve switch?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Questions 25

Which is true of the phone lines on a Digital Alarm Communicator Transmitter (DACT) when no other methods are in use?

Options:

A.

Phone lines must be dedicated.

B.

Primary line should be connected to the PSTN.

C.

Test signal must be sent every 24 hours.

D.

Two separate phone lines are required.

Buy Now