Labour Day Sale - Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 575363r9

Welcome To DumpsPedia

NS0-593 Sample Questions Answers

Questions 4

You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need to know the storage limits.

In this scenario, which source should be reviewed?

Options:

A.

NetApp Cloud Volumes ONTAP Release Notes

B.

Hardware Universe

C.

Interoperability Matrix Tool (IMT)

D.

Cloud Central

Buy Now
Questions 5

A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log.

Which FIFO message Is useful for Investigating this Issue?

Options:

A.

before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A

B.

BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11

C.

before Reset BBSP:C=00 L=00 FIFO:

D.

ONTAP Shutdown BBSP:C=00 L=2F FIFO:

Buy Now
Questions 6

You have connection Issues from a Linux host to an AFF A400 FC LUN. You are asked by support to run the NetApp sanlun command to provide troubleshooting information.

Which NetApp software package must be installed on the host?

Options:

A.

Virtual Storage Console

B.

Inventory Collect Tool

C.

Host Utilities package

D.

SnapDrive for UNIX

Buy Now
Questions 7

A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment.

What Information would you tell your customer in this scenario?

Options:

A.

The AUSO feature cannot be activated due to a non-mirrored aggregate.

B.

The AUSO feature is not available in Metrocluster IP installations by design.

C.

A faulty link automatically deactivated the AUSO feature.

D.

This is a configuration failure, you can activate that feature for the customer.

Buy Now
Questions 8

The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.

PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)

What has happened in this situation?

Options:

A.

While in maintenance mode, the sldiag device show command was executed.

B.

While in maintenance mode, the fcadmin device_map command was executed.

C.

While in maintenance mode, the HA_config show command was executed.

D.

While in maintenance mode, the mailbox destroy local command was executed.

Buy Now
Questions 9

Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.

Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?

Options:

A.

In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.

B.

The cables are cabled Incorrectly on the SAS stack.

C.

This situation is normal for a FA57750 single-node system.

D.

Active IQ Is not aware of the shelf configuration for a single-node system.

Buy Now
Questions 10

A customer is calling you to troubleshoot why users are unable to connect to their CIFS SVM.

Referring to the Information shown in the exhibit, what Is the source of the problem?

Options:

A.

The v1db database is offline.

B.

The aggregate aggr2 has a failed disk.

C.

The databases On Node03 must be Switched from secondary to master.

D.

The broken disk in Node03 is the source of the problem.

Buy Now
Questions 11

You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated from Node 2, interface e0b.

In this scenario, what should you do first to solve this problem?

Options:

A.

Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.

B.

Replace the motherboard on Node 2.

C.

Replace both NetApp CN1610 switches.

D.

Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.

Buy Now
Questions 12

An administrator receives the following error message:

What are two causes for this error? (Choose two.)

Options:

A.

There Is excessive SSD load causing the wear leveling to become unbalanced.

B.

A disk is falling.

C.

There is excessive SATA HDD load.

D.

An SSD disk is performing garbage collection to create a dense data layout.

Buy Now
Questions 13

Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports that the server's FC HBA port Is online, but the LUN does not show up.

Referring to the exhibit, what is the reason for this problem?

Options:

A.

The FC service has not been configured on the SVM.

B.

The zoning on the FC switches Is Incorrect.

C.

The LUN Is not mapped to the correct SCSI ID.

D.

The esxserver igroup contains incorrect IQNs.

Buy Now
Questions 14

Your customer has mounted an NFS SVM from a Linux client unci performance is very poor. The customer is certain that they have jumbo frames enabled. They have verified an MTU of 9000 on both the Linux client and the broadcast domain on the NetApp ONTAP 9.8 cluster.

Referring to the exhibit, which ONTAP command will help isolate a possible MTU mismatch?

Options:

A.

B.

C.

D.

Buy Now
Questions 15

Which two throughput elements are controlled by host applications? (Choose two.)

Options:

A.

operation size

B.

Jitter

C.

concurrency

D.

latency

Buy Now
Questions 16

After a motherboard replacement on a NetApp AFF A300 in a SAN environment, the customer states that ports 0e and 0f are unable to connect to the fabric. The ports report "offline".

What would you examine first to troubleshoot the issue?

Options:

A.

vserver fcp wwpn-alias show command output

B.

system node hardware unified-connect show command output

C.

storage port show command output

D.

vserver fcp interface show command output

Buy Now
Questions 17

A customer reports that some of their client computers are unable to access a FlexGroup over CIFS. This problem involves only their older Windows XP clients and some printers and scanners.

In this scenario, which statement Is correct?

Options:

A.

FlexGroup requires CIFS shares to be located in qtrees, which these clients do not support.

B.

FlexGroup requires CIFS shares to use the Continuously Available Feature, which these clients do not support.

C.

These systems use the SMQI protocol which Is an unsupported feature in FlexGroup

D.

These systems use Offloaded Data Transfer, which is an unsupported feature in FlexGroup.

Buy Now
Questions 18

When you review performance data for a NetApp ONTAP cluster node, there are back-to-back (B2B) type consistency points (CPs) found occurring on the loot aggregate.

In this scenario, how will performance of the client operations on the data aggregates be affected?

Options:

A.

During B2B processing, clients will be unable to write data.

B.

Data aggregates will not be affected by B2B processing on another aggregate.

C.

During B2B processing, all I/O to the node is stopped.

D.

During B2B processing, clients will be unable to read data.

Buy Now
Exam Code: NS0-593
Exam Name: NetApp Certified Support Engineer ONTAP Specialist
Last Update: Apr 18, 2024
Questions: 60
$64  $159.99
$48  $119.99
$40  $99.99
buy now NS0-593